Original article in translation · historical calculations

“Scientists study what already exists; engineers create what has never existed before.”

I am neither a scientist nor an inventor. I do not invent new pumps or manufacture insulation for building walls. I simply understand the great variety of technical products on the market and am willing to share that knowledge with anyone interested.

Only the most sophisticated users make it to the second most important section. Here is why.

When you begin rationalizing your system, either on your own or with my help, it means you have already minimized energy losses and all the equipment at your disposal is operating properly. At the optimization stage we are going to make all of that equipment work together as a system, in accordance with your very specific circumstances.

I want to give you the tools to save gas and electricity.

The most common way a user controls a heating system is with the thermostat on a gas boiler. You probably turn the boiler off when you leave home for a long time, or set its thermostat to minimum. This is a normal and rational way to switch off heating during an extended absence.

However, if the heating system was designed with standard radiators, on your return you may have to wait one or two days for the temperature to rise from zero to even 18–20°C. This happens because design standards assume a gradual change in indoor temperature following the usually gradual changes outdoors. In normal conditions the radiators are perfectly adequate, but if you want to heat the house quickly you must wait.

There are several ways to solve this problem:

  • For around $100, you can buy a programmable room thermostat, lower the temperature to 5°C when you leave and program it to raise the temperature to 20°C two days before your planned return.
  • For around $500, you can install a GSM control system for your boiler (and perhaps other devices), allowing you to switch heating between normal and standby modes by SMS.

If your house has rooms used rarely or intermittently — a pantry, dressing room or guest room, for example — you can reduce gas use by setting the radiator’s thermostatic head to “1” or “*” (frost protection).

For industrial enterprises, rationalization means setting the heating system to match the operating schedule. For example, in offices from 5 p.m. to 6 a.m., and all day on weekends, the temperature could be set to 14–18°C and raised to 20–22°C between 6 a.m. and 5 p.m.

Remember: lowering the indoor temperature by one degree can save up to 5% of heating costs.

Another way to save gas is to make appropriate use of alternative heat sources.

The most common two-boiler systems at the time were gas + firewood (coal) and firewood (coal) + electricity.

For natural gas, it is important to understand that the tariffs set by Ukraine’s energy regulator for households rose with annual gas consumption:

  1. up to 2,500 m³/year — UAH 0.72/m³;
  2. 2,501–6,000 m³/year — UAH 1.10/m³;
  3. 6,001–12,000 m³/year — UAH 2.25/m³;
  4. more than 12,000 m³/year — UAH 2.69/m³.

Yet these tariffs, in force at the time of writing (18 March 2014), did not encourage households to save gas, since all other fuels were more expensive even than gas in the fourth consumption category — over 12,000 m³ a year.

That is why, if you have a private house, my recommendation at that time was to burn firewood in a solid-fuel boiler only when you had cut it yourself or obtained it for at most half the market price.

If you have non-residential property (a commercial business), the standard gas price was UAH 2.90/m³ regardless of volume. At that price, converted into the cost per kWh of heat, natural gas, firewood, coal and fuel pellets were almost equal for businesses. So if you run a business, it made little difference: burn whatever you have. If someone demands an astronomical amount for designing and installing a gas pipeline, remember that you are paying mainly for the convenience of gas, since a gas boiler needs almost no attention.

The same considerations apply to a pair of boilers using electricity and firewood. If gas for households was four times cheaper than wood and about ten times cheaper than electricity, it made sense to make the solid-fuel boiler the main source and the electric boiler the backup (emergency) source, setting the latter to 20–30°C on the flow side.

For businesses at the time (18 March 2014), using firewood and coal was three times cheaper than direct electric heating.

There is much talk about heat pumps, but as we can see, even 300% efficiency (which is not always attainable) will not guarantee savings under every tariff.

I consider further recommendations about rational use of existing equipment unnecessary: there are too many possible combinations to describe within a reasonable number of letters.

Note: the quoted prices and tariffs refer to 2014, not to current energy tariffs.

Original Russian article · The full series

All articles in the series